IO-Link sensor/actuator hubs for IP69K environments (Washdown Line)
Interface
IO-Link 1.1
Operating voltage Ub
18...30.2 VDC
Connection (COM 1)
M12x1-Male, 4-pin, A-coded
Connection (supply voltage IN)
M12x1-Male, 5-pin, L-coded
Connection slots
8x M12x1-Female, 5-pin, A-coded
Do you have any questions about the product?
This product page contains information for China – Balluff Automation (Shanghai) Co., Ltd
Alternative products
|
Alternative
|
|
![]() |
![]() |
|
BNI IOL-314-S52-P071
3,343.95 CNY
List price
|
BNI IOL-314-S52-P012
3,153.30 CNY
List price
|
|
Interface | IO-Link 1.1 | IO-Link 1.1 |
---|---|---|
Operating voltage Ub | 18...30.2 VDC | 18...30.2 VDC |
Connection (COM 1) | M12x1-Male, 4-pin, A-coded | M12x1-Male, 4-pin, A-coded |
Connection (supply voltage IN) | M12x1-Male, 5-pin, L-coded | - |
Connection slots | 8x M12x1-Female, 5-pin, A-coded | 8x M12x1-Female, 5-pin, A-coded |
Digital inputs | 16x PNP/NPN, Type 1, Type 3 | 16x PNP/NPN, Type 1, Type 3 |
Digital outputs | 16x PNP | 16x PNP |
Configurable inputs/outputs | yes | yes |
Extension port | yes | yes |
Single-channel monitoring | yes | yes |
Additional function |
Vibration Internal temperature Device discovery |
Vibration Internal temperature Device discovery |
Current sum US, sensor | 2 A | 2 A |
Switching current |
12x 2 A 4x 4 A |
16x 2 A |
Current sum UA, actuator | 16 A | 4 A |
Housing material |
PBT, GF30 1.4404 stainless steel, Inserts |
PBT, GF30 1.4404 stainless steel, Inserts |
Dimension | 68 x 38.3 x 183.5 mm | 68 x 38.3 x 183.5 mm |
Ambient temperature | -25...70 °C | -25...70 °C |
IP rating | IP68, IP69K, when threaded in | IP68, IP69K, when threaded in |
Transfer rate | COM3 (230.4 kBaud) | COM3 (230.4 kBaud) |
Process data cycle min. | 2 ms | 2 ms |
Process data IN | 12 bytes | 12 bytes |
Process data OUT | 2 bytes | 2 bytes |
Secondary features |
Identification Device Discovery Signal Delay Signal Speed Monitor Switching Counter Operating Hours Counter Boot Cycle Counter Voltage and Current Monitoring Extreme Environment Status Variant Configuration |
Identification Device Discovery Signal Delay Signal Speed Monitor Switching Counter Operating Hours Counter Boot Cycle Counter Voltage and Current Monitoring Extreme Environment Status Variant Configuration |
Secondary features for condition monitoring |
Vibration monitoring Internal temperature monitoring |
Vibration monitoring Internal temperature monitoring |